数据采集步骤为:
Data acquisition steps: (1) input control point coordinates: Enter the file name easy to remember (such as class code or name initials). Enter dot PT #, usually from the surface, a beginning (can also be a string name). Followed by input N (X), E (Y), Z (H) coordinate data. After you've finished entering coordinates into a point the next input, dot PT # Automatic 1. (2) The whole set equipment: In the test site right in leveling instrument, press the power switch devices [POWER], rotate the telescope, so that total station into the observed state, then [MENU] key to enter the main menu. (3) input data collection file name: In the main menu, select Data Acquisition (DATA COLLECT), input data collection file name. (4) Enter the test site data: the data acquisition menu, select F1 (OCC. PT # INPUT), respectively, enter the test site dots (PT #) or the coordinates (N, E, Z), station code (ID ), apparatus, high (INS HT). (5) Input data after the point of view: In the data acquisition menu, press F2 (BACKSIGHT) to enter after the point of view (orientation point) data to set the state. Press F4 (BS) key to enter the orientation point coordinates or orientation angle. (6) Orientation: When the test site data and post-perspective data entry is complete, press F3 (MEAS) key, and then awarded after the point of view, select a measurement mode, such as press F2 (SD) key, enter the slant range measurement; Press F3 (NEZ) key, and enter the coordinate measuring. (7) scrap the Department of Measurement: awarded goal (Prism), followed by input point number, coding, target high (lens height), select a measurement [such as slope distance (SD) or the coordinates (NEZ)] began to measure and record . (8) Data recording: ① file status (FILE STATUS) ② Search (SEARCH) ③ Document Management (FILE MAINTAN) ④ input coordinates (COORD.INPUT) ⑤ Delete coordinates (DELETE COORD) ⑥ Input Encoding (PCODE INPUT) ⑦ Data send (DATA TRANSFER) ⑧ Initialization (INITIALIZE) Total station to set communication parameters Parameters the following settings can not be based on the actual situation in some settings. ① confirmed that the data is stored into the total station in memory or transmitted to the peripheral, if it is transmitted to the peripheral, you need to set the RS-232C serial port to open. ② Set Total Station measurement, generally as "horizontal angle, zenith distance, slope distance" measurement. ③ Set Total Station side length of observation modes, generally in the "fine measurements, coarse measurement, tracking," select "fine test" or "track" mode. ④ Set Total Station measurement of the number of side length of the observation, usually one second. ⑤ Set the baud rate of total station communication parameters: There are 1200,2400,4800, ... ... and so on. ⑥ to set communication parameters calibration methods: There are N (no), O (odd), E (even), etc.. |
上一个:[资料]野外数据采集及内业成图 下一个:[资料]编码度盘测角和动态光栅度盘测角原理 |
![]() ![]() ![]() |