1、简述数字测图系统的组成
采集、输入、存储、管理、计算、输出
由两大部分组成:采集数据设备、过程控制设备。
分类:积木式、整体式
3、在全站仪技术指标中3+2ppm*d,各个参数的意义?
3代表仪器的固定误差,ppm是百万分之(几)的意思,D是全站仪或者测距仪实际测量的距离值,单位是公里
4、简述红外线测距仪原理
不利用时间,利用红外线载波相位的相位差来计算距离。
5、了解编码度盘测角原理(了解)
6、了解动态光栅度盘测角原理(了解)
7、在用全站仪正式测量以前,应进行什么设置?
A、测站点位、坐标、高程、仪器高B、起测方向C、保存文件名D、测量模式
测量前的准备有:a、电池的安装和检查 b、垂直度盘和水平度盘指标的设置
c、倾角的自动补偿与使用倾角显示进行整平d、仪器参数的设置
8、简述使用全站仪实施数据采集的步骤和所作的设置?
见补充
9、什么叫波特率
数据传输速度
10、全站仪与计算机进行数据通讯时需要设置哪些参数
波特率、数据位、检校位、停止位
1, outlining the composition of the Digital Mapping System
Collection, input, storage, management, computing, the output
2, total station primarily by which of these components and the total station's classification?
Consists of two parts: data collection equipment, process control equipment.
Category: building block type, the overall style
3, in the total station specifications in the 3 +2 ppm * d, the significance of each parameter?
3 represents the apparatus of fixed error, ppm is parts per million (several) means, D is the total station or a range finder measured the distance between the actual value, in units of km
4, outlining principles of infra-red range finder
Do not use time and using infra-red carrier phase of the phase difference to calculate the distance.
5 to understand the encoding-degree angle-measuring plate theory (Learn)
6, degree of understanding of the dynamic grating angle measuring plate theory (Learn)
7, using the formal measurement of total station before what should be set up?
A, test site, place, coordinates, elevation, equipment Gao B, measured from the direction of C, save the file name D, measurement mode
Measurement of pre-prepared are: a, battery installation and inspection b, vertical and horizontal dial indicator dial settings
c, dip angle display and use of automatic compensation for leveling d, instrument parameters and settings
8, outlining the implementation of the use of total station data collection steps and the settings?
See Supplementary
9, What is the baud rate
Data transfer rate
10, total station and computer data communications when the need to set which parameters
Baud rate, data bits, calibration bits, stop bits |